Simply put u factor measures how well a window keeps heat inside your home.
U factor windows and doors.
Windows doors and skylights protect you from the elements just like a winter coat.
The mandatory maximum u factor for manufactured fenestration products has been maintained at 0 58.
Parts of a window or door with a window installed inside of the door which are assessed for the u value rating include.
We specialize in supplying products to builders contractors architects and homeowners throughout the greater puget sound area.
It s a particularly important measure for climates with colder winters.
An r value difference of 1 2 points is infinitesimal as it relates to overall efficiency and energy compliance.
Windows skylights or sliding doors must have a glazing u factor of less than 0 57 and a solar heat gain coefficient of less than 0 40.
Slab but not the windows or doors that are part of the same envelope.
Lower numbers indicate greater insulating capabilities.
Window or door hardware.
Nfrc u factor ratings however represent the entire window performance including frame and spacer material.
While some windows doors and skylights are better at keeping you warm others excel at keeping you cool.
For superior energy performance select windows with a u factor of 0 25 or less.
Window or door frame.
U factor is the rate at which a window door or skylight conducts non solar heat flow.
But like a winter coat you should pick the windows doors and skylights that make the most sense for your climate.
It s a measure of total heat flow through a window or door from room air to outside air.
For windows skylights and glass doors a u factor may refer to just the glass or glazing alone.
With the 2019 title 24 energy standards update the prescriptive maximum u factor for all fenestration products windows glass doors skylights has been changed to 0 30 in all climate zones.
We aim to help our customers make sound decisions based on both design preferences and budget constraints.
When referring to architecture the word fenestration is defined as the arrangement of windows and doors on the elevations of a building.
If air conditioning is not a concern look for a higher solar heat gain coefficient shgc of 0 35 0 60 so winter solar heat can help offset the heating energy need.
When reviewing a u value as an r value r value 1 u value we see that what might be considered an inefficient u value is actually.
If there are discrepancies noted or the windows doors have no nfrc stickers or are site built then the builder must either revised the title 24 compliance report to demonstrate that the project will comply with the default assumptions in table 110 6 u factor and shgc or replace the windows doors with nfrc compliant ones.
At u factor window door we offer quality window door and skylight products from reputable manufacturers.